thumb|Finger tip carboxyhemoglobin saturation monitor.|alt=NOTE I would suggest that this article use as its example device a standalone CO-oximeter. Use the blood-gas-attached and 'peripheral' devices as alternative devices. A pulse CO-oximeter is a non-invasive, multi-wavelength instrument that measures the oxygen carrying state of hemoglobin in a blood specimen, including oxygen-carrying hemoglobin (O2Hb), non-oxygen-carrying but normal hemoglobin (HHb) as well as the dyshemoglobins such as carboxyhemoglobin (COHb) and methemoglobin (MetHb). Pulse CO-oximeters use four or more wavelengths w
thumb|Finger tip carboxyhemoglobin saturation monitor.|alt=NOTE I would suggest that this article use as its example device a standalone CO-oximeter. Use the blood-gas-attached and 'peripheral' devices as alternative devices. A pulse CO-oximeter is a non-invasive, multi-wavelength instrument that measures the oxygen carrying state of hemoglobin in a blood specimen, including oxygen-carrying hemoglobin (O2Hb), non-oxygen-carrying but normal hemoglobin (HHb) as well as the dyshemoglobins such as carboxyhemoglobin (COHb) and methemoglobin (MetHb). Pulse CO-oximeters use four or more wavelengths whereas the common pulse oxymeter uses only two. Simpler oximeters measure only the ratio of oxyhemoglobin to total 'bindable' hemoglobin (i.e. oxyhemoglobin + deoxyhemoglobin-HHb) and as a result will incorrectly report the true oxygen saturation in patients with significant dyshemoglobin levels. CO-oximetry is useful in defining the causes for hypoxemia, or hypoxia, (oxygen deficiency at the tissue level).
==Mechanism== A CO-oximeter measures the absorption of light passing through blood at multiple wavelengths of light to several dozens of wavelengths, in order to distinguish oxyhemoglobin, and deoxyhemoglobin, and thus determine the oxyhemoglobin saturation (the percentage of oxygenated hemoglobin compared to the total amount of available hemoglobin (Hb)). Measurement of greater numbers of wavelengths enables the instrument to distinguish between these and carboxyhemoglobin,-COHb, methemoglobin -metHb, other hemoglobin moieties and 'background' light-absorbing species. Traditionally, measurement is made from arterial blood processed in a specific device designed to be able to measure proportions of multiple components of several hemoglobin moieties using multi-wavelength spectrophotometry and complex, but straightforward internal computations. While these units still are in wide use, blood gas analyzers with integral CO-oximetry modules have also been developed and successfully marketed by several manufacturers. More recently, some 'pulse' or more precisely 'peripheral' oximeters have made it possible to estimate carboxyhemoglobin with non-invasive technology similar to a simple (peripheral) pulse oximeter. In contrast, the use of a standard or simple pulse oximeter is not effective in the diagnosis of CO poisoning as patients who have carbon monoxide poisoning may have a normal oxygen saturation reading on a pulse oximeter.
Discovered by embedding cosine similarity (sentence-transformers MiniLM, 384-dim).